描述 |
产品编号 |
|
Features:
• Si over InGaAs (1.7µm, 2.05µm, 2.2µm or 2.6µm)
• Active Area Top Detector(2.0mm or 5.0mm)
• Active Area Bottom Detector (1.0mm, 2.0mm or 3.0mm)
• InGaAs (1.7µm) over InGaAs (1.7µm, 2.05µm, 2.2µm and 2.6µm)
• Active Area Bottom Detector (1.0mm or 2.0mm)
• Standard Package (TO-5 and TO-8)
Applications:
• Optical Pyrometry
• Dual-Band Spectroscopy
• Flame Monitor
• Non-Contact Radiometry
|
|
Features:
• Small Diameter (40µm)
• 800nm to 1800nm Spectral Response
• Linear and Geiger Mode Operation
• High Sensitivity
• Fiber Pigtail (Single or Multi Mode) including Hi-Reliability Pigtail
• Thermoelectric Cooling Available
• Packages (TO-46 and sub-mount)
Applications:
• Optical Time Domain Reflectometer (OTDR)
• Optical Communications
• Photon Counting
|
|
Features:
• Small Diameter (60µm to 300µm)
• Cutoff Wavelength (1.7µm)
• Low Dark Current for High Sensitivity
• Low Capacitance for High Speed (2.5 GHz)
• Packages (TO-46) including Fiber Pigtail, Hi-Reliability Fiber Pigtail, Receptacle and Sub-mounts
Applications:
• Optical Communications
• Time Resolved Fluorescence Measurements
• LED/LD Temporal Characterization
• Laser Detection and Range Finder (LADAR)
• Light Detection and Ranging (LIDAR)
• Free Space Optics (FSO)
|
|
Features:
• Active Diameter (0.5mm to 5mm)
• Cutoff Wavelength (1.7µm)
• High Shunt Resistance for High Sensitivity
• Multiple Lens Selection (Biconvex, Planoconvex, or Ball)
• Optical Filters (Neutral Density and Bandpass)
• Packages (TO-46, TO-18, TO-5 or TO-8)
Applications:
• NIR Sensing/Radiometry
• LED/LD Characterization
• Medical Diagnostics
• Spectroscopy
• Raman Spectroscopy
• Spectroscopy
• Astronomy/Photometry
|
|
Features:
• Active Diameter (0.3mm to 3mm)
• Cutoff Wavelength (1.9µm, 2.05µm, 2.2µm and 2.6µm)
• High Shunt Resistance
• Multiple Lens Selection (Biconvex, Planoconvex, or Ball)
• Packages (TO-46, TO-18 or TO-5)
Applications:
• Gas Sensing Monitor
• Hydrocarbon Sensor
• Flame/Spark Detection
• FTIR
• Spectroscopy
• SWIR Photodetection
|
|
Features:
• Active Diameter (80µm to 350µm)
• 900nm to 1650nm Spectral Response
• Linear Operation
• Low Dark Current for High Sensitivity
• Low Capacitance for High Speed
• Fiber Pigtail (Single or Multi Mode) including Hi-Reliability or Hi-Rel Pigtail
• Packages (TO-46 and Sub-mount with Ball Lens Option)
Applications:
• Free Space Optics (FSO)
• LIDAR/LADAR
• High Sensitivity Photometry
• Optical Communications
• Optical Time Domain Reflectometer (OTDR)
|
|
Features:
• Single Stage or Dual Stage TE Cooler
• Active Area (0.3mm to 5mm)
• High Shunt Resistance
• Low Dark or Leakage Current
• High Sensitivity
• Cutoff Wavelength (1.7µm, 1.9µm, 2.05µm, 2.2µm and 2.6µm)
• Standard Package (TO-5, TO-8, TO-66)
• Custom Package with Fiber Pigtail, SMA Receptacle
• RoHS Compliant
Applications:
• NIR Photometry/Radiometry
• Spectroscopy
• Gas Sensing
• FTIR
• Raman Spectroscopy
• Medical Diagnostics
|
|
Features:
• 800nm to 1700nm Spectral Response
• Active Diameter (0.5mm, 1.0mm, 1.5mm, 2.0mm and 3.0mm)
• High Sensitivity
• Low Crosstalk
• High Shunt Resistance
• Low Dark Current
• Low Capacitance for High Segment Bandwidth
• Standard Package (TO-18 and TO-5)
Applications:
• Beam Alignment
• Laser Guidance
• Optical Tweezers
• Beam Profiling
|
|
Features:
• Si over InGaAs (1.7µm, 2.05µm, 2.2µm or 2.6µm)
• Active Area Top Detector(2.0mm or 5.0mm)
• Active Area Bottom Detector (1.0mm, 2.0mm or 3.0mm)
• InGaAs (1.7µm) over InGaAs (1.7µm, 2.05µm, 2.2µm and 2.6µm)
• Active Area Bottom Detector (1.0mm or 2.0mm)
• Standard Package (TO-5 and TO-8)
Applications:
• Optical Pyrometry
• Dual-Band Spectroscopy
• Flame Monitor
• Non-Contact Radiometry
|